Re-playing the vm-setup/setup-playbook causes subsequent provisioning to fail

    XMLWordPrintable

    Details

    • Type: Bug
    • Status: Done
    • Priority: Medium
    • Resolution: Done
    • Labels:
      None

      Description

      If an error occurs during the run of the setup-playbook, then the values of the MAC address may not agree between the network.xml, baremetalvm.xml, and ironic_nodes.json.  This caused ironic provisioning to fail for me.

      The root cause is that the MAC addresses are generated randomly on each run of the playbook.